Procedures for Deep Space Imaging

Background: Astrophotography deep space imaging requires several different instruments and a few different software programs.
It is essential that the correct steps are taken, in the correct order, to achieve good results.
The following are the detailed steps that I take when I am setting up for astrophotography of deep space objects. These steps are specific to my hardware and software configuration.

Deep Space Imaging Procedures:
1) Make sure that the imaging camera is mounted onto the imaging scope. If a focal reducer or field flattener is to be used, make sure it is attached along with any spaces required for backfit. Attached power and USB cables.
3) For best results, the mount should be balanced with the imaging equipment and polar aligned. This should all be done prior to starting to image.
4) Turn-on the main power strip.
5) Turn on computer and log onto the computer.
6) Turn-on the power strip on the pier.
7) Set the winch for the roll-off roof to free-wheel and pull the end of the winch cable around the external pulley and back to the roof.
8) Make sure the rain wedges are removed from around the outside 4X4’s.
9) Make sure the internal turn-bolts holding down the roof are in the unbuckled position.
10) Turn-on the power to the mount.
11) Using mount hand controller, command the mount to ‘Zero Position’.
12) Using the mount hand controller, set the speed to 9 and then slew the mount so the scopes are below the level of the roof.
13) Set the winch to normal and winch the roof to the end of the extension beam.
14) Rewind the winch slightly to give some slack.
15) Unhook the winch and re-hook directly to the eye attached to the roof for pulling the roof back.
16) Using the winch, take up all of the slack.
17) Remove the scope covers.
18) Add scope dew shields.
19) Using the mount hand controller, command the mount to perform a 1 star alignment. Then select a star and have controller slew to that star.
20) Turn on red-dot light.
21) Using mount hand controller, slew the mount to center the alignment star and complete the star alignment.
22) Turn off red dot light.
23) Activate Unity Platform software. Then select both PowerBox and Falcon Rotator.
24) Activate iOptron Commander and then select ‘Mount’. Make sure that the mount Meridian flip is correctly selected and the mount GPS has functioned properly.
25) Activate Optec FocusLynx Commander software and select the hub for the USB focuser depending upon which focuser(s) are going to be connected. Then connect the all focusers.
26) Activate PHD2 program and select the appropriate configuration. Then connect both the camera and the mount. Start the guiding camera and refocus as required. If planning on calibrating, perform Calibration Assistant.
27) Using mount hand controller, select the object to image and slew to that object.
28) Activate Sequence Generator Pro. Then select the appropriate profile. I have several pre-made provides for different equipment setups and conditions.
29) In Sequence Generator Pro connect all devices.
30) Select the directory that the images will be stored in.
31) Perform rough focus using ‘Frame & Focus’.
32) Perform ‘Focus Control’ to perform automated focusing for best focus.
33) Perform platesolve using ‘Framing and Mosiac Wizard’.
34) Select the desired target and then frame the target.
35) Once the target is properly framed, click on ‘Create Sequence’. Edit the name of the sequence then click on the ‘OK’ box.
36) Update the sequencer with appropriate type, exposure duration binning, filters, repeats, etc. In order to make sure target remains centered, make duplicate events. This will force a new platesolve.
37) Run the sequence. This will automatically re-focus, perform platesolve on the selected object, turn on the autoguider, and then start imaging.
38) Sequence Generator Pro will continue to take images, autofocus as required, re-platesolve as required, and monitor autoguiding until all of the events are complete.
39) At completion of the sequence, add event for taking flats. In order to make sure platesolve does not slew the mount, uncheck all other events and disable the mount.
40) Slew the mount so that the scopes are vertical. Remove all dew shields.
41) Connect flat panel to wall outlet and then put the flat panel on top of the imaging scope.
42) Run Sequence Generator Pro flats event with the flat exposures. Generally the exposures are <1 second based on the Flats Wizard. I take 50 flats.
43) When flats are acquired, unplug the flat panel and put it back in its holding place.
44) Slew the mount so that the scopes are clear of the roof line.
45) Using winch, roll the roof back in its normal position.
46) Replace scope covers.
47) Using mount hand control command ‘zero position’.
48) Using mount hand control command ‘park’.
49) Power down the mount.
50) Turn off all computer applications.
51) Command computer to shutdown.
52) Turn Pier power off.
53) Turn off main power.
54) The next day I turn on the power and turn on the the observatory computer and, using Remote Desktop, I download all of the images, focusing data, guiding data, and SGP logs to my home computer. I then shutdown the observatory computer and power.

Click Below Image for Full Size:

M1

Click to Return to Home Page
Click to Return to Home Page Click to Return to Home Page