NGC 185

Also Known as: Caldwell 18

Object Type: Dwarf Spheroidal Galaxy

Constellation: Cassiopeia

Distance from Earth: 2.05 million light years

Apparent Magnitude: 9.2

Coordinates: RA 00H 38M 57.97S DEC 48deg 20min 14.56sec

Actual Size: 10,000 light years in diameter

Apparent Dimensions: 11.7 arc-minutes x 10.9 arc-minutes

--------------------------------------------------------------------------

Environmental Data

Date: October 13, 2021     Start Time: 7:22PM     End Time: 2:07AM     SQM: 18.53

Moon Age: 8.3 days     Moon Culmination: 7:35PM     Moon Illumination: 59.2%

Temperature: 63 degrees F    Humidity: 88%    Dew Point: 59 degrees F

Location: Westport, Massachusetts 02790    Sky Condition: Partly cloudy

Comment: Polar aligned mount previous night. PHD2 calibration good. PHD2 Guiding Assistant utilized to update guiding parameters.

--------------------------------------------------------------------------

Imaging Scope Data

Mount: iOptron CEM120     Camera: ZWO ASI2600 OSC     Focuser: Optec QuickSync FT20

Telescope: Celestron 11 inch SCT Edge   Focal Length: 1960mm

Focal Reducer/Field Flattener: 0.7 focal reducer    Filter: None

Rotator: Manual rotator     Power Control: Pegasus Ultimate Powerbox V2     Dew Heater: Kendrick dew strip

Imaging Software

Mount: iOptron Commander     Focuser: Optec FocusLynx Commander

Imaging: Sequence Generator Pro     Platesolve: ASTAP     Rotator/Control: Pegasus Unity Platform

Imaging Status

Imaging Software: Sequence Generated     Focus HFR 3.46    Platesolve: Good on 3rd attempt    

--------------------------------------------------------------------------

Guide Scope Data

Telescope: Stellarvue SVX130 refractor    Camera: Lodestar Focuser: Optec DirectSync SV35

Dew Heater: Kendrick dew strip    Software: PHD2    Exposure: 1 sec    Binning: 1x1    Tracking Result: 0.5 arc-seconds RMS

--------------------------------------------------------------------------

Images Taken

Number of light frames: 43 usable        Duration: 2 minutes        Gain: 100        

Camera Temperature: -10 degrees C        Binning: 1x1        F-Stop: 10.0        

Total Integration Time: 1.43 hours

--------------------------------------------------------------------------

Number of flat frames: 50        Duration: 0.2        Gain: 100        

Camera Temperature: -10 degrees C        Binning: 1x1        F-Stop: 10.0        

Flat Field Illumination: All-Pro 'Spike-a-Flat Field standard' illuminated panel

--------------------------------------------------------------------------

Number of Dark frames: 50 (from library)       Duration: 2 minutes        Gain: 100        

Camera Temperature: -10 degrees C        Binning: 1x1        F-Stop: 10.0        

--------------------------------------------------------------------------

Number of Bias frames: 50 (from library)        Duration: 0.001 seconds        Gain: 100        

Camera Temperature: -10 degrees C        Binning: 1x1        F-Stop: 10.0        

--------------------------------------------------------------------------

Imaging Processing

Imaging Processing Software: PixInsight

Processes utilized: Linear - calibration/integration: Flats ImageCalibration with Master Bias, Flat ImageIntegration, Images ImageCalibration with Flat Master & Dark Master, Debayer, SubFrameSelector, StarAlign, ImageIntegration

Linear - Background extraction, Color correction, deconvolution, noise reduction: DynamicBackgroundExtraction, ImageSolve, SpectroPhotometricColorCalibration, BlurXTerminator, NoiseXTerminator

Non-Linear: GeneralizedHyperbolicStretch script, CurvesTransformation, MultiScaleLinearTransform for sharpening, CurvesTransformation, StarReduction script.

--------------------------------------------------------------------------

Notes: After imaging found that scope balance was way off. Rebalanced.

Click Below Image for Full Size:

M1 Click to Return to Home Page
Click to Return to Home Page